OCPP 1.6j Configuration Settings#
Key |
Default value |
Readonly |
Reboot required |
Accessible |
Supported |
Documentation |
|---|---|---|---|---|---|---|
AllowOfflineTxForUnknownId |
false |
false |
false |
true |
Yes |
Specification |
AuthorizationCacheEnabled |
false |
Yes |
Specification |
|||
AuthorizationKey |
false |
false |
false |
Yes |
OCPP 1.6j Security Whitepaper |
|
AuthorizeRemoteTxRequests |
false |
false |
false |
true |
Yes |
Specification |
BlinkRepeat |
false |
No |
Specification |
|||
ChargeProfileMaxStackLevel |
12 |
true |
false |
true |
Yes |
Specification |
ChargingScheduleAllowedChargingRateUnit |
“A” |
true |
false |
true |
Yes |
Specification |
ChargingScheduleMaxPeriods |
48 |
true |
false |
true |
Yes |
Specification |
ClockAlignedDataInterval |
0 |
false |
false |
true |
Yes |
Specification |
ConnectionTimeOut |
300 |
false |
false |
true |
Yes |
Specification |
ConnectorPhaseRotation |
No |
Specification |
||||
ConnectorPhaseRotationMaxLength |
No |
Specification |
||||
ConnectorSwitch3to1PhaseSupported |
false |
true |
Yes |
Specification |
||
GetConfigurationMaxKeys |
30 |
true |
false |
true |
Yes |
Specification |
HeartbeatInterval |
86400 |
false |
false |
true |
Yes |
Specification |
LightIntensity |
No |
Specification |
||||
LocalAuthListEnabled |
true |
false |
false |
true |
Yes |
Specification |
LocalAuthListMaxLength |
48 |
false |
false |
true |
Yes |
Specification |
LocalAuthorizeOffline |
true |
false |
false |
true |
Yes |
Specification |
LocalPreAuthorize |
false |
false |
false |
true |
Yes |
Specification |
MaxChargingProfilesInstalled |
10 |
true |
false |
true |
Yes |
Specification |
MaxEnergyOnInvalidId |
False |
Specification |
||||
MeterValueSampleInterval |
60 |
false |
false |
true |
Yes |
Specification |
MeterValuesAlignedData |
“” |
false |
false |
true |
Yes |
Specification |
MeterValuesAlignedDataMaxLength |
8 |
true |
false |
true |
Yes |
Specification |
MeterValuesSampledData |
“” |
false |
false |
true |
Yes |
Specification |
MeterValuesSampledDataMaxLength |
8 |
true |
false |
true |
Yes |
Specification |
MinimumStatusDuration |
0 |
false |
false |
true |
Yes |
Specification |
ReserveConnectorZeroSupported |
true |
false |
false |
true |
Yes |
Specification |
ResetRetries |
2 |
false |
false |
true |
Yes |
Specification |
SendLocalListMaxLength |
48 |
true |
false |
true |
Yes |
Specification |
StopTransactionOnEVSideDisconnect |
true |
false |
false |
true |
Yes |
Specification |
StopTransactionOnInvalidId |
true |
false |
false |
true |
Yes |
Specification |
StopTxnAlignedData |
“” |
false |
false |
true |
Yes |
Specification |
StopTxnAlignedDataMaxLength |
Yes |
Specification |
||||
StopTxnSampledData |
“” |
false |
false |
true |
Yes |
Specification |
StopTxnSampledDataMaxLength |
8 |
true |
false |
true |
Yes |
Specification |
SupportedFeatureProfiles |
“” |
true |
false |
true |
Yes |
Specification |
SupportedFeatureProfilesMaxLength |
Yes |
Specification |
||||
SupportedFileTransferProtocols |
Https |
true |
Partial |
Specification |
||
TransactionMessageAttempts |
3 |
false |
false |
true |
OCPP |
Specification |
TransactionMessageRetryInterval |
60 |
false |
false |
true |
OCPP |
Specification |
WebSocketPingInterval |
180 |
false |
false |
true |
Yes |
Specification OCPPJ only |
Cst_AuthorizationTimeout |
20 |
false |
false |
true |
Yes |
TBD |
Cst_FreeVendActive |
false |
false |
false |
true |
Yes |
TBD |
Cst_FreeVendIdTag |
“” |
false |
false |
true |
Yes |
TBD |
Cst_MaxCurrentRotarySwitchSetting |
true |
false |
false |
true |
Yes |
See Below |
Cst_MeterValuesInTxOnly |
true |
false |
false |
true |
Yes |
TBD |
Cst_PreBootTransactions |
false |
false |
false |
true |
Yes |
TBD |
Cst_SilentOfflineTransactions |
false |
false |
false |
true |
Yes |
TBD |
Cst_StopTxnDataCapturePeriodic |
false |
false |
false |
true |
Yes |
TBD |
Cst_TxStartOnPowerPathClosed |
false |
false |
false |
true |
Yes |
TBD |
Some settings are either not avaliable for provisioning or modification, due to product features, or not supported when not relevant. Since amina offers factory customer-optimized provisioning, some OCPP settings default values may be tailored and thereby different than the values listed here.
Custom Configuration Settings Documentation#
Cst_PreBootTransactions#
When true this setting allows transactions to start before the OCPP BootNotification has succeeded. Default value is false.
Cst_SilentOfflineTransactions#
When true this setting allows charging in scenarios where a Transaction is not guaranteed to generate a valid charge data record for a session. Default value is false.
E.g if the EVSE goes offline, can it continue to charge without sending StartTx / StopTx to the server when going online again. Mostly used to offer continued use of device, e.g that Driver can charge their car when unexpected failures occur, such as the current offline OCPP journal is out of space, or in situations with partial hardware failure where the device is waiting to be replaced by a technician.
Cst_TxStartOnPowerPathClosed#
Sets the point in time for a Transaction to start.
false(default): Tx start point is when charging is authorized and cable is pluggedtrue: Tx start point is when the vehicle actually started charging
Cst_MaxCurrentRotarySwitchSetting#
Returns the maximum current setting of the rotary switch, if available. This setting is not part of the OCPP specification and is specific to amina products. This setting can also be used to check if the charger is in factory reset mode. Possible values are:
Possible Values |
Description |
|---|---|
unknown |
Max current rotary switch not read yet |
RESET |
Max current rotary switch set to RESET |
6A |
Max current rotary switch set to 6A |
8A |
Max current rotary switch set to 8A |
10A |
Max current rotary switch set to 10A |
13A |
Max current rotary switch set to 13A |
16A |
Max current rotary switch set to 16A |
18A |
Max current rotary switch set to 18A |
20A |
Max current rotary switch set to 20A |
25A |
Max current rotary switch set to 25A |
32A |
Max current rotary switch set to 32A |